GeneratorsCan you clean a generator without dismantling it?

Short answer
Yes. Stator and rotor can also be cleaned in situ, using custom-manufactured nozzles and lances reaching behind the windings. For generators, Egger PowAir uses cold dry compressed air alongside dry ice: dry, residue-free, and up to 24 bar so gentle that windings and insulating layers are not damaged.
As of November 2026
Cleaning without dismantling.
Stator and rotor are deeply cleaned using nozzles and lances specially manufactured for this application, even in areas that are otherwise inaccessible: on the windings, behind the components of a stator, and on the rotor. Whether the contamination is dry or oily makes no difference.
For generators, Egger PowAir uses the Cold PowAir process alongside dry ice: cold dry compressed air and nothing else, a further development based on Cold Jet technology. No solids or particles are blasted onto the surface. The cleaning is dry, residue-free, and does not attack the surface.
What is is cleaned.
From the complete generator to individual poles. Practical applications from Egger PowAir.
| Component | What is done |
|---|---|
| Generator in situ | Stator and rotor are deeply cleaned using special lances. |
| Stator, dismantled | End windings at every angle, even behind the windings. |
| Rotor with mounted poles | Gentle cleaning without damaging the insulating layers. |
| Slots on the stator | Adhesive residue in the slot guide, on the laminated core, and on the slot bottom, without damaging the components behind. |
| Laminated core | Strip paint from the surface without bending the individual laminations. |
| Poles as individual components | Strip paint or refurbish. |
| Hazardous material remediation | PCB-containing paint layers and asbestos-containing insulation. |
Procedure on site.
- Technical assessmentSystem, contamination, and downtime window are clarified in advance, with a site visit report and photographic documentation.
- Risk analysisRisk assessment and measures are sent to the plant operator and team leader prior to the deployment.
- CleaningA team of at least two skilled technicians in protective equipment, one person cleans, one secures.
- CompletionDelivery note, customer report, and photographic documentation before and after.
Project from practice.
Slot model with silicone residue
- Initial situation
- Fully cross-linked silicone residue on a slot model.
- Process
- Cold PowAir, in situ
- Result
- Requirement 100% fulfilled, residue completely removed without dismantling the parts.
“Egger PowAir Cleaning … has carried out all cleaning work commissioned to date for our hydroelectric generators to our complete satisfaction.”
Frequently asked questions.
Does the generator have to be dismantled for this?
No. Stator and rotor can also be cleaned in situ. Custom-manufactured nozzles and lances are available for this purpose, reaching behind the windings.
Are windings and insulation damaged?
No. Up to 24 bar, the Cold PowAir process is so gentle that highly sensitive components of a generator and their windings can be cleaned without damaging the surface.
What happens to oily contamination?
It is removed just like dry contamination. Whether the contamination is dry or oily makes no difference.
Can the deployment be scheduled during downtime?
Yes. Egger PowAir is mobile across Europe so that downtimes are utilised optimally. Available round the clock on 00800 2532 6464, toll-free from all over Europe.