Boiler systemsBoiler cleaning: Dry ice or glass beads?
Short answer
For slag and hard caking in biomass and incineration plants, mostly glass beads: hot compressed air with PowAir Glasspearls at up to 24 bar cleans and tempers the metal surface at the same time, confirmed by TÜV Süd. Dry ice and cold dry compressed air remain reserved for generators and electrical systems.
As of November 2026
The honest answer.
Slag and caking in incineration plants are often as hard as concrete. For boilers, superheaters, and heat exchangers in biomass combined heat and power plants, Egger PowAir therefore does not use dry ice, but Hot PowAir: hot compressed air with PowAir Glasspearls at up to 24 bar.
The glass beads strike at an angle of approximately 45 to 90 degrees. They remove the deposits and simultaneously smooth, compact, and temper the metal surface, the so-called Egger-Dengel-Effekt. A test report from TÜV Süd confirms this. Dry ice and cold dry compressed air remain reserved for generators, electrical systems, and sensitive components.
What is is cleaned.
| Plant component | What is done |
|---|---|
| Tube bundles and heat exchangers | Deep cleaning and surface finishing |
| Superheater bundles | Remove caking |
| Economiser (ECO) | Cleanliness for better residual heat utilisation |
| Post-combustion | Honeycomb and catalytic converter cleaning |
| Air preheater (LUVO) | For heat recovery |
| Condensers | Every design and size |
| Combustion chamber | Push grate, fire grate, refractory care, ash chute |
| Turbines and generators | Dedicated know-how for turbines and generators |
| Filter systems | Electrostatic precipitators, bag filters, wet ash extractors |
| Pipelines and membrane walls | With specialist tools, from the evaporator to the circulating boiler |
From the field.
“In a day and night shift, the superheater and the tube bundles were cleaned in tip-top condition. There was caking that was like concrete. … The cleaning effort is only 50% of previous cleaning times.”
“We had an emergency at our plant … The firebox and the steam boiler were cleaned sparkling clean within a single day.”
Frequently asked questions.
Can a biomass boiler be cleaned with dry ice?
For hard caking and slag, Hot PowAir with Glasspearls is usually the more effective method. It cleans and tempers the metal surface in a single operation. For generators and electrical systems, Egger PowAir uses cold dry compressed air or dry ice.
What is the Egger-Dengel-Effekt?
During blasting with hot compressed air and PowAir Glasspearls, metal surfaces are not only cleaned, but also smoothed, compacted, and tempered, similar to shot peening. TÜV Süd confirmed this in a comparative study on steel pipe surfaces.
Is this also possible in an emergency?
Yes. Egger PowAir can be reached around the clock, free of charge from all over Europe on 00800 2532 6464, and works in day and night shifts if required.
How often should a boiler be cleaned?
Many operators have the plant cleaned during the routine overhaul. The appropriate interval is determined by the technical assessment.